APOGEE Observations

APOGEE Observational Strategy

APOGEE acquires 300 spectra simultaneously in a single observation with a state-of-the-art, cryogenic, near-infrared spectrograph. The actual spectral data acquisition relies upon plugplates, which are aluminum disks placed in the focal plane of the telescope. Each plate corresponds to a specific patch of sky and is pre-drilled with holes corresponding to the sky positions of objects in that area. A targeted area of the sky is covered by one or more unique plates. DR14 presents results for 823 different plugplates in 731 fields.

For APOGEE, almost all plugplates are observed multiple times on different nights to allow for the identification of binary star systems as for a particular object, variations in radial velocity over time indicate the (likely) presence of a companion. Each one of these observations is called a visit, and visits are identified with a plate number and the MJD (Modified Julian Date) on which that plate was observed. As stated above, plates with 3 or more visits are observed with a specified cadence.

Plate Plugging

When the observatory is ready to observe a plate, the observatory staff plug optical fibers into the holes drilled into the plates, and map which fibers correspond to which holes (and therefore which objects) by shining light through each fiber from the slit ends. These mapping data are incorporated into one of the Header and Data Units (HDUs) of the apPlate file described below.

Each hole on each plate corresponds to one object on the sky. The fibers plugged into each hole bring the light from the telescope focal plane to the (pseudo)slit of the spectrograph. Thus, each spectrum is also referenced by the number of the fiber (fiberID) at the pseudoslit with which it was collected. Plates used by the APOGEE survey have 300 fibers.

Raw Data Collection

Observers mount cartridges containing the plugged plates on the telescope.   A series of 500s exposures are acquired for each plate. In general, 8 exposures are obtained for a particular plate during a visit, although this number can vary based on available time, observing conditions, etc.

The resolution of the APOGEE spectra in comparison to the pixel size of the APOGEE detectors causes the spectrum from a single exposure to slightly undersample the resolution at the short wavelength end. To avoid the challenges of working with undersampled data, APOGEE spectra are taken in pairs, with the detectors shifted slightly (by a distance of one half of a detector pixel) between the two exposures of the pair; we refer to this shifting as dithering, and each "dither pair" of exposures includes observations at these offset dither positions. A standard 8-exposure APOGEE observing sequence consists of exposures at the two differ dither positions (A and B) and typically taken in the pattern ABBA ABBA. The data reduction requires exposures in dither pairs, so that any unpaired exposure is discarded.

The APOGEE infrared detectors have the capability to be read "non-destructively", meaning that the amount of charge per pixel can be detected without affecting that charge. This permits the levels on the detectors to be measured during the exposure. While readout noise can be significant for a single read of the detectors, the ability to read them multiple times during an exposure allows for a reduction in the net readout noise in the final exposure. For APOGEE, the detectors are read in an "up-the-ramp" mode where the detectors are read every 10.7 seconds. Thus, a single exposure generally consists of 47 readouts over an exposure time of 500 seconds. Because of the multiple readouts, the raw APOGEE data for an exposure are actually in a "data cube", with two of the dimensions representing the location on the detectors and the third dimension representing the time sequence.

Observational Data Products

If a plate is observed on more than one MJD, in general the fibers will be replugged; thus, even for the same plugplate, a given fiberID on different MJDs may correspond to different objects on the sky, and the same star will generally be observed with a different fiberID at each visit. The individual visit spectra for objects are available in apVisit FITS files.

Sample APOGEE spectra for stars of different spectral types (click for a larger image). Gaps in the spectra correspond to gaps in detector coverage.
Sample APOGEE spectra for stars of different spectral types (click for a larger image). Gaps in the spectra correspond to gaps in detector coverage.

In addition to the individual visit spectra, the sum of these spectra is available. The APOGEE software pipeline co-adds the spectra for each particular star coming from different visits to the same field to produce a higher signal-to-noise spectrum of each object. These combined spectra are identified by the catalog name of each star. The APOGEE sample is selected almost exclusively from the 2MASS catalog, and thus the stellar identifications are by their APOGEE ID, which basically just encodes the position of the star on the sky from the Two Micron All-Sky Survey (2MASS). The combined spectra are a primary data product of the APOGEE survey. As described in the data access description, the combined spectra are provided in apStar files in FITS format. The image to the right shows examples of some typical APOGEE spectra for stars of different spectral types.

Because of the nature of infrared observing, various instrumental features, and the still-developing state of the reduction pipeline, there are important things to be aware of when looking at the APOGEE spectra. For more information about these important considerations, read the page on Using APOGEE Spectra, as well as the information about the APOGEE pipeline.